How To Solve The Drip Problem of Vial Filling Machine?
How To Solve The Drip Problem of Vial Filling Machine?
How To Solve The Drip Problem of Vial Filling Machine?
August 14, 2023
1. Check the problem of the equipment itself to determine whether the ball valve in the vial filling machine is damaged or loose. If the reason is the internal ball valve, the solution is to replace the internal ball valve. If the internal ball valve is damaged, there is no way to repair it and it can only be replaced with a new one.

2. Check whether the syringe assembly is clean. If it is not clean, it will lead to an unclean blockage between the inner and outer tubes, so the filling part should be removed, cleaned, sterilized and maintained.

3. Check whether the fuel nozzle is complete. If the filling nozzle is damaged, the vial filling machine will drip during operation. Replace the damaged feed nozzle, check the other feed nozzle for use, aging or corrosion, and replace it as soon as possible.

4. Check whether the O-ring is corroded or worn. If the O-ring is corroded or worn, it will also cause the filling machine to drip. Therefore, in this case, it is recommended to replace the O-ring.

5. Check the cylinder position. Determine whether the cylinder is in the middle support position of the cylinder, and check whether the cylinder piston and piston rod are firm, if loose, please lock. If the fault position of the cylinder changes, you need to reinstall the cylinder and ensure that the position is correct.

Although the drip problem is not large, if it is not solved, it may affect the efficiency and quality of our subsequent work. Therefore, it is necessary to pay attention to its drip problem, repair the problem in time, and then improve the service life of the vial bottle filling machine. The quality and quality of the production products will also be improved.